CSRental

ATEX fan heater TEH-70

This all-round ATEX fan heater TEH-70 is the smallest fan heater available for use in explosion-prone zones….

Featured specs
Suitable for zones 1, 2, 21 & 22
Air displacement 1,050 m³/h

Category:

Description

This all-round ATEX fan heater TEH-70 is the smallest fan heater available for use in explosion-prone zones. The ATEX fan heater TEH-70 can be used in both gas (zone 1) and dust (zone 21) environments.

Due to the H2 coding, the explosion-proof heater can also be used in Atex environments, such as water treatment plants, where hydrogen is present.

For temporary climate solutions for business, industry, construction and ATEX environments, CSrental B.V. is the place to be.
CSrental B.V. has professional consultants who can work with you to find the best rental solution for your business.
Call or email us for a customized quote.

Minimum rental period: 7 days

ATEX code zone 1 & 2 II 2G Ex h Ex db eb IIB+ H2 T3 Gb

ATEX code zone 21 & 22 II 2D Ex tb IIIC T200° Db IP65

Heating capacity 6 kW

Air displacement 1,050 m³/h

Connection voltage 400V / 50 Hz

Power input 6 kW

Recommended fuse 16A

Plug connection 400V / 16A – 5 pin CEAG

Air hose connection ø 350 mm outlet (max. 5 meters)

Dimensions L x W x H 540 x 450 x 490 mm

IP class 55

Weight 35 kg

Mobility portable

 

 

Related products

  • Extra gegevens

    Isolated300mm / 12in6m20°C / + 120°CN0-2,500

    Application Diameter Length Temperature range ATEX Pressure Range
    Default 80mm / 3in 6m -20°C / +100°C N 0-2,500 Pa
    Default 100mm / 4in 6m -20°C / +100°C N 0-2,500 Pa
    Default 125mm / 5in 6m -20°C / +100°C N 0-2,500 Pa
    Default 160mm / 6in 6m -20°C / +100°C N 0-2,500 Pa
    Default 200mm / 8in 10m -20°C / +100°C N 0-2,500 Pa
    Default 250mm / 10in 10m -20°C / +100°C N 0-2,500 Pa
    Default 300mm / 12in 10m -20°C / +100°C N 0-2,500 Pa
    Default 350mm / 14in 10m -20°C / +100°C N 0-2,500 Pa
    Default 400mm / 16in 10m -20°C / +100°C N 0-2,500 Pa
    Default 450mm / 18in 10m -20°C / +100°C N 0-2,500 Pa
    Default 500mm / 20in 10m -20°C / +100°C N 0-2,500 Pa
    Default 550mm / 22in 10m -20°C / +100°C N 0-2,500 Pa
    Default 600mm / 24in 10m -20°C / +100°C N 0-2,500 Pa
    Default 800mm / 32in 10m -20°C / +100°C N 0-2,500 Pa
    Isolated 450mm / 18in 6m -20°C / +120°C N <0 – 2,500
    Isolated 600mm / 24in 6m -20°C / +120°C N <0 – 2,500
    Isolated 500mm / 20in 10m -20°C / +120°C N <0 – 2,500
    Isolated 600mm / 24in 10m -20°C / +120°C N <0 – 2,500
    Antistatic (ATEX) 200mm / 8in 5m – 10m -20°C / +100°C J Vacuum: 4,000 Pa / Pressure: 14 kPa
    Antistatic (ATEX) 250mm / 10in 5m – 10m -20°C / +100°C J Vacuum: 4,000 Pa / Pressure: 14 kPa
    Antistatic (ATEX) 300mm / 12in 5m – 10m -20°C / +100°C J Vacuum: 4,000 Pa / Pressure: 14 kPa
    Antistatic (ATEX) 400mm / 16in 5m -20°C / +100°C J Vacuum: 4,000 Pa / Pressure: 14 kPa
    Antistatic (ATEX) 450mm / 18in 5m – 10m -20°C / +100°C J Vacuum: 4,000 Pa / Pressure: 14 kPa
    Antistatic (ATEX) 500mm / 20in 5m – 10m -20°C / +100°C J Vacuum: 4,000 Pa / Pressure: 14 kPa
    Antistatic (ATEX) 600mm / 24in 5m – 10m -20°C / +100°C J Vacuum: 4,000 Pa / Pressure: 14 kPa
    Air distribution hose 300mm / 12in 5m – 10m -20°C / +100°C N 0 – 1,500 Pa
    Air distribution hose 400mm / 16in 5m – 10m -20°C / +100°C N 0 – 1,500 Pa
    Air distribution hose 500mm / 20in 5m – 10m -20°C / +100°C N 0 – 1,500 Pa
  • Extension cables

    View the range of extension cables here.
    Extra gegevens
    Extension cables Connection voltage Plug Length Diameter ATEX zone
    Default 230V 230V / 16A CEE 7/7 type E/F 25m 3*2.5mm² n/a
    230V 230V / 16A 230 V / 16 A – 3 pole 15m 3*2.5mm² n/a
    400V 400V / 16A 400 V / 16 A – 5 pin 25m 5*2.5mm² n/a
    400V 400V / 32A 400 V / 32 A – 5 pin 25m 5*6mm² n/a
    400V 400V / 63A 400 V / 63 A – 5 pin 25m 5*16mm² n/a
    400V 400V / 125A 400 V / 125 A – 5 pin 25m 5*35mm² n/a
    ATEX 42V 42V / 16A ATX 42V / 16A – 3 pin 25m 3*2.5mm² zone 1 and 21
    230V 230V / 16A CEAG 230 V / 16 A – 3 poles 25m 3*2.5mm² zone 1 and 21
    400V 400V / 16A CEAG 400 V / 16 A – 3 poles 25m 5*2.5mm² zone 1 and 21
    400V 400V / 32A CEAG 400 V / 32 A – 5 pin 25m 5*6mm² zone 1 and 21
    400V 400V / 63A CEAG 400 V / 63 A – 5 pin 25m 5*16mm² zone 1 and 21
  • General accessories

    View the range of general accessories here
    Extra gegevens

    View the range of general accessories here:

    Item Sizes Suitable for suction side Suitable for press silk
    Connection socket for connecting attachments 100 to 800 mm J J
    Coupling bush for connecting pipes 100 to 800 mm J J
    T-piece 100 to 800 mm J J
    Y piece 100 to 800 mm J J
    Y-piece flexible 130 to 600 mm N J
    Flange edge 100 to 800 mm J J
    Control valve 100 to 800 mm J J
    45° bend 100 to 800 mm J J
    90° bend 100 to 800 mm J J
    Expiry 100 to 600 mm J J
    Very flexible from 300mm N J
    Filter cartridges 100 to 600 mm J J
    Clamp Band 80 to 800 mm n/a n/a