CSRental

Oil fired heater ID 1200 M

The ID 1200 M (also known as IMA200RHP) is a mobile, indirectly fired diesel heater,…

Featured specs
Capacity 200 kW (17.2414 kcal)
Fuel consumption max. 19.4 (l/h)
Air displacement 13,000 m³/h

Category:

Description

The ID 1200 M (also known as IMA200RHP) is a mobile, indirectly fired diesel heater, equipped with an EC high-pressure fan, a soft starter and automatic phase recognition.
As a result, the machine can be installed quickly and several air transport hoses can be placed without any problems.
The EC motor and automatic burner control with thermostat connection ensure that the machine does not consume more energy than strictly necessary.

Thanks to the intercal industrial burner with flow control, the stove supplies 200 kW of clean warm air with a delta ΔT of approx. 47°C.

The burner chamber is heat resistant up to 850°C and is a high efficiency heat exchanger (92%).

There is a possibility to connect hoses through the 600 mm hose connection. This makes it possible to target heating.

Please note that there must be sufficient room ventilation during use and when you connect air transport hoses, they must be suitable for use at high temperatures.

Minimum rental 7 days

Capacity 200 kW (17.2414 kcal)

Fuel consumption max. 19.4 (l/h)

Air displacement 13,000 m³/h

Max. fan back pressure 500 Pa

Power consumption4 kW / 10 A

Connection voltage400 V / 50 Hz

Plug connection 400 V – 16 A / 5 pin or 32 A / 5 pin

Dimensions L x W x H 2,170 x 910 x 1,520 mm

Weight 450 kg

Discharge cone Ø 600 mm / 4 x 300 mm / 2 x 400 mm / 2 x 500 mm

Chimney connection Ø 200 mm

Hose length per connection Click here for the overview

Thermostat connectionYes

Applications

Agriculture:
– Heating of workspace and storage sheds;
– Drying of agricultural products and bulbs to prevent harmful ethylene formation.

Horticulture:
– Heating greenhouses and polytunnels without the risk of harmful CO2 and CO emissions;
– Heating of sorting areas Industry;
– Heating halls and storage sheds, defrosting pipes and installations.

Build:
– Heating and drying of construction sites and construction projects;
– Drying of buildings after flooding.

Events:
– ID 1200 M is particularly suitable for heating tents and showrooms.

Related products

  • Spark arrestor

    View the range of the different variants of flue gas discharge here.
  • General accessories

    View the range of general accessories here
    Extra gegevens

    View the range of general accessories here:

    Item Sizes Suitable for suction side Suitable for press silk
    Connection socket for connecting attachments 100 to 800 mm J J
    Coupling bush for connecting pipes 100 to 800 mm J J
    T-piece 100 to 800 mm J J
    Y piece 100 to 800 mm J J
    Y-piece flexible 130 to 600 mm N J
    Flange edge 100 to 800 mm J J
    Control valve 100 to 800 mm J J
    45° bend 100 to 800 mm J J
    90° bend 100 to 800 mm J J
    Expiry 100 to 600 mm J J
    Very flexible from 300mm N J
    Filter cartridges 100 to 600 mm J J
    Clamp Band 80 to 800 mm n/a n/a
  • Meter climate control

    View the range of meters for climate control here.
    Extra gegevens

    View the range of meters for controlling machines below.

    Atex thermostaat
    ATEX thermostat
    II 2G IIC T4 – II 2D IIIC T130
    CO² regulation Data logger Dew point control Digital thermostat and hygrostat Differential pressure gauge
    Type thermostat CO² protection delete received dehumidification thermostat and hygrostat ventilation
    Control of temperature air quality monitoring dew point monitoring temperature and humidity air volume
    Deployment area Heating ventilation heating, cooling, dehumidification and humidification dehumidifiers heating, cooling, dehumidification and humidification operational reliability ventilation
    Measure value -40 – +40 °C 0 – 2,000ppm 0 – 100 % RH
    -40 – 70+ °C
    0 – 100% RH 0 – 100 % RH
    -20 – 80+ °C
    0 – 500 Pa
    Accuracy 2% +/- 2% +/- 2% +/- 2% +/- 1.5% +/- 2% +/-
    Switching range 2.5A / 230V 230 V Battery 3.6V 2 A / 230 V 2 A / 230 V 2 A / 230 V
    Hygrostaat adsorptiedroger
    Hygrostat
    Suitable for MDC adsorption dryers
    Plug-in humidistat
    Suitable for 230 V dryers
    Plug thermostat
    Suitable for 230 V heaters
    Thermostat
    Suitable for the DFE 65 and 95
    Thermostat
    Suitable for the DFE 80 T
    Thermostat oil heaters
    Type humidistat plug hygrostat plug thermostat thermostat thermostat thermostat
    Control of humidity humidity temperature temperature temperature temperature
    Deployment area dehumidification and humidification dehumidification and humidification heating heating heating heating
    Measure value 30 – 100% RH 10 – 90 % RH 0 – 60% RH 0 – 40% RH 0 – 40% RH 0 – 40% RH
    Accuracy 3% +/- 5% +/- 5% +/- 3% +/- 3% +/- 3% +/-
    Switching range 5 A / 230 V
    2 A / 230 V
    2 A / 230 V 2 A / 230 V 25 A / 400 V 2 A / 230 V 2 A / 230 V
  • Fuel tank

    View the range of fuel tanks here.
  • (flexbile) Chimney

    View the range of the different variants of flue gas discharge here.
  • Extension cables

    View the range of extension cables here.
    Extra gegevens
    Extension cables Connection voltage Plug Length Diameter ATEX zone
    Default 230V 230V / 16A CEE 7/7 type E/F 25m 3*2.5mm² n/a
    230V 230V / 16A 230 V / 16 A – 3 pole 15m 3*2.5mm² n/a
    400V 400V / 16A 400 V / 16 A – 5 pin 25m 5*2.5mm² n/a
    400V 400V / 32A 400 V / 32 A – 5 pin 25m 5*6mm² n/a
    400V 400V / 63A 400 V / 63 A – 5 pin 25m 5*16mm² n/a
    400V 400V / 125A 400 V / 125 A – 5 pin 25m 5*35mm² n/a
    ATEX 42V 42V / 16A ATX 42V / 16A – 3 pin 25m 3*2.5mm² zone 1 and 21
    230V 230V / 16A CEAG 230 V / 16 A – 3 poles 25m 3*2.5mm² zone 1 and 21
    400V 400V / 16A CEAG 400 V / 16 A – 3 poles 25m 5*2.5mm² zone 1 and 21
    400V 400V / 32A CEAG 400 V / 32 A – 5 pin 25m 5*6mm² zone 1 and 21
    400V 400V / 63A CEAG 400 V / 63 A – 5 pin 25m 5*16mm² zone 1 and 21
  • Hose manifold oil heaters

    View the hose distributors for the oil-fired heaters here.
  • Extra gegevens

    Isolated300mm / 12in6m20°C / + 120°CN0-2,500

    Application Diameter Length Temperature range ATEX Pressure Range
    Default 80mm / 3in 6m -20°C / +100°C N 0-2,500 Pa
    Default 100mm / 4in 6m -20°C / +100°C N 0-2,500 Pa
    Default 125mm / 5in 6m -20°C / +100°C N 0-2,500 Pa
    Default 160mm / 6in 6m -20°C / +100°C N 0-2,500 Pa
    Default 200mm / 8in 10m -20°C / +100°C N 0-2,500 Pa
    Default 250mm / 10in 10m -20°C / +100°C N 0-2,500 Pa
    Default 300mm / 12in 10m -20°C / +100°C N 0-2,500 Pa
    Default 350mm / 14in 10m -20°C / +100°C N 0-2,500 Pa
    Default 400mm / 16in 10m -20°C / +100°C N 0-2,500 Pa
    Default 450mm / 18in 10m -20°C / +100°C N 0-2,500 Pa
    Default 500mm / 20in 10m -20°C / +100°C N 0-2,500 Pa
    Default 550mm / 22in 10m -20°C / +100°C N 0-2,500 Pa
    Default 600mm / 24in 10m -20°C / +100°C N 0-2,500 Pa
    Default 800mm / 32in 10m -20°C / +100°C N 0-2,500 Pa
    Isolated 450mm / 18in 6m -20°C / +120°C N <0 – 2,500
    Isolated 600mm / 24in 6m -20°C / +120°C N <0 – 2,500
    Isolated 500mm / 20in 10m -20°C / +120°C N <0 – 2,500
    Isolated 600mm / 24in 10m -20°C / +120°C N <0 – 2,500
    Antistatic (ATEX) 200mm / 8in 5m – 10m -20°C / +100°C J Vacuum: 4,000 Pa / Pressure: 14 kPa
    Antistatic (ATEX) 250mm / 10in 5m – 10m -20°C / +100°C J Vacuum: 4,000 Pa / Pressure: 14 kPa
    Antistatic (ATEX) 300mm / 12in 5m – 10m -20°C / +100°C J Vacuum: 4,000 Pa / Pressure: 14 kPa
    Antistatic (ATEX) 400mm / 16in 5m -20°C / +100°C J Vacuum: 4,000 Pa / Pressure: 14 kPa
    Antistatic (ATEX) 450mm / 18in 5m – 10m -20°C / +100°C J Vacuum: 4,000 Pa / Pressure: 14 kPa
    Antistatic (ATEX) 500mm / 20in 5m – 10m -20°C / +100°C J Vacuum: 4,000 Pa / Pressure: 14 kPa
    Antistatic (ATEX) 600mm / 24in 5m – 10m -20°C / +100°C J Vacuum: 4,000 Pa / Pressure: 14 kPa
    Air distribution hose 300mm / 12in 5m – 10m -20°C / +100°C N 0 – 1,500 Pa
    Air distribution hose 400mm / 16in 5m – 10m -20°C / +100°C N 0 – 1,500 Pa
    Air distribution hose 500mm / 20in 5m – 10m -20°C / +100°C N 0 – 1,500 Pa