CSRental

Attachments

Showing 1–9 of 43 results

  • (flexbile) Chimney

    View the range of the different variants of flue gas discharge here.
  • Extra gegevens
    Application Diameter Length Temperature range ATEX Pressure Range
    Default 80mm / 3in 6m -20°C / +100°C N 0-2,500 Pa
    Default 100mm / 4in 6m -20°C / +100°C N 0-2,500 Pa
    Default 125mm / 5in 6m -20°C / +100°C N 0-2,500 Pa
    Default 160mm / 6in 6m -20°C / +100°C N 0-2,500 Pa
    Default 200mm / 8in 10m -20°C / +100°C N 0-2,500 Pa
    Default 250mm / 10in 10m -20°C / +100°C N 0-2,500 Pa
    Default 300mm / 12in 10m -20°C / +100°C N 0-2,500 Pa
    Default 350mm / 14in 10m -20°C / +100°C N 0-2,500 Pa
    Default 400mm / 16in 10m -20°C / +100°C N 0-2,500 Pa
    Default 450mm / 18in 10m -20°C / +100°C N 0-2,500 Pa
    Default 500mm / 20in 10m -20°C / +100°C N 0-2,500 Pa
    Default 550mm / 22in 10m -20°C / +100°C N 0-2,500 Pa
    Default 600mm / 24in 10m -20°C / +100°C N 0-2,500 Pa
    Default 800mm / 32in 10m -20°C / +100°C N 0-2,500 Pa
    Isolated 300mm / 12in 6m 20°C / + 120°C N 0-2,500
    Isolated 450mm / 18in 6m -20°C / +120°C N <0 – 2,500
    Isolated 600mm / 24in 6m -20°C / +120°C N <0 – 2,500
    Isolated 500mm / 20in 10m -20°C / +120°C N <0 – 2,500
    Isolated 600mm / 24in 10m -20°C / +120°C N <0 – 2,500
    Antistatic (ATEX) 200mm / 8in 5m – 10m -20°C / +100°C J Vacuum: 4,000 Pa / Pressure: 14 kPa
    Antistatic (ATEX) 250mm / 10in 5m – 10m -20°C / +100°C J Vacuum: 4,000 Pa / Pressure: 14 kPa
    Antistatic (ATEX) 300mm / 12in 5m – 10m -20°C / +100°C J Vacuum: 4,000 Pa / Pressure: 14 kPa
    Antistatic (ATEX) 400mm / 16in 5m -20°C / +100°C J Vacuum: 4,000 Pa / Pressure: 14 kPa
    Antistatic (ATEX) 450mm / 18in 5m – 10m -20°C / +100°C J Vacuum: 4,000 Pa / Pressure: 14 kPa
    Antistatic (ATEX) 500mm / 20in 5m – 10m -20°C / +100°C J Vacuum: 4,000 Pa / Pressure: 14 kPa
    Antistatic (ATEX) 600mm / 24in 5m – 10m -20°C / +100°C J Vacuum: 4,000 Pa / Pressure: 14 kPa
    Air distribution hose 300mm / 12in 5m – 10m -20°C / +100°C N 0 – 1,500 Pa
    Air distribution hose 400mm / 16in 5m – 10m -20°C / +100°C N 0 – 1,500 Pa
    Air distribution hose 500mm / 20in 5m – 10m -20°C / +100°C N 0 – 1,500 Pa
  • Camlock pressure regulator

    The pressure regulator with camlock connection is available in 1¼” and 2″.
  • CTM Monitoring

    CTM monitoring is a climate monitoring system.
    Extra gegevens

    How does CTM climate monitoring work?

    CTM monitoring works by means of a GPS signal. The monitoring is equipped with a 230V connection. The system consists of wirelessly coupled sensor modules. The data collected by these sensors are sent to a portal and are only visible to you, the customer. In the portal, these sensor modules can also be set up.

    There are various sensors, these sensors are used to measure various quantities and units. These include:

    • Temperature;
    • Relative humidity;
    • Pressure (difference);
    • Carbon dioxide.

    The user-friendly portal of the CTM monitoring system makes monitoring easy. In the portal, measured data are visualised and compared with pre-set limit values.
    When values are exceeded, an alarm that can be received by e-mail or SMS follows. The advantage of the CTM system is that measurement results can be analysed directly online. With one system; spraying and blasting operations, storage areas, cold stores and freezers, ect. are monitored.
    Once the process is complete, all data can be downloaded as a PDF file. If necessary, this can be added to files as evidence.

  • Extension cable

    View the range of extension cables here.
    Extra gegevens
    Extension cables Connection voltage Plug Length Diameter ATEX zone
    Default 230 V 230V / 16A CEE 7/7 type E/F 25m 3*2.5mm² n/a
    230V 230V / 16A 230 V / 16 A – 3 pole 25m 3*2.5mm² n/a
    400V 400V / 16A 400 V / 16 A – 5 pin 25m 5*2.5mm² n/a
    400V 400V / 32A 400 V / 32 A – 5 pin 25m 5*6mm² n/a
    400 V 400V / 63A 400 V / 63 A – 5 pin 25m 5*16mm² n/a
    400 V 400V / 125A 400 V / 125 A – 5 pin 25m 5*35mm² n/a
    ATEX 42V 42V / 16A ATX 42V / 16A – 3 pin 25m 3*2.5mm² zone 1 and 21
    230V 230V / 16A CEAG 230 V / 16 A – 3 poles 25m 3*2.5mm² zone 1 and 21
    400 V 400V / 16A CEAG 400 V / 16 A – 3 poles 25m 5*2.5mm² zone 1 and 21
    400 V 400V / 32A CEAG 400 V / 32 A – 5 pin 25m 5*6mm² zone 1 and 21
    400V 400V / 63A CEAG 400 V / 63 A – 5 pin 25m 5*16mm² zone 1 and 21
  • External pump 16

    The pump is an accessory for the CSC 16 Chiller Minimum rental: 7 days Power consumption0.75 kW Connection voltage 400 V / 50 Hz / 16 A IP class55 Nominal speed2.885 1/min Nominal current1.7 A Maximum pressure8 barr Cooling methodWater Maximum capacity100 l/min Maximum discharge head21 m Fluid temperatuur-10°C – +110°C CouplingCamlock 1¼” Dimensions L...
  • External pump 38

    The pump is an accessory for the CSC 38 Chiller Minimum rental: 7 days
  • External pump 75

    The pump is an accessory for the CSC 75 Chiller Minimum rental: 7 days Power consumption2.2 kW Connection voltage 400 V / 50 Hz / 16 A IP class55 Nominal speed2.880 1/min Nominal current4.56 A Maximum pressure16 barr Cooling methodWater Maximum capacity500 l/min Maximum discharge head34 m Fluid temperatuur-25°C – +120°C CouplingCamlock 2″ Dimensions L...