CSRental

Adsorption dryer TTR-2800

The adsorption dryer TTR-2800 is equipped with technology according to the highest industrial requirements. This dryer is…

Featured specs
Amount of dry air (nominal) 2,800 m³/h at 300 Pa.
Reactivation air volume 570 m³/h at 300 Pa

Category:

Description

The TTR-2800 adsorption dryer is suitable for a wide variety of tasks such as room air dehumidification and process drying within industry, logistics or utilities.

The unit can operate in recirculation mode, and is especially suitable for low temperature and low humidity operation.

For temporary climate solutions for business, industry, construction and ATEX environments, you have come to the right place at CSrental B.V.

CSrental B.V. has professional advisors who will work with you to find the best rental solution for your business.

Call or e-mail us for a tailor-made quotation.

Minimum rental period: 7 days

Amount of dry air (nominal) 2,800 m³/h, at 300 Pa

Regeneration air volume 570 m³/h, at 300 Pa

Dehumidification capacity at 20 °C / 60% R.H. 376.4 kg / 24 h

Input power 21.6 kW / 31.7 A

Plug connection 400V / 32A – 5 pin

Connection voltage 400V / 50 Hz

Hygrostat optional

Noise level 70 dB(A)

Mobility forklift

Dimensions L x W x H1,348 x 769 x 1,323 mm excl. frame

Weight 250 kg excl. frame kg

Process air hose connection 315 mm

Regeneration air hose connection 200 mm

Warning:

In polluted environments where the adsorption dryer is active, it is essential to change the filters regularly. This ensures that the adsorption dryer continues to function optimally.

Before commissioning the adsorption dryer, survey the room and take any measures where necessary. The adsorption dryer must not be used in:

  • Environments where particles, gas, smoke and the like may be sucked in due to negative pressure created, which may adversely affect chimneys, furnaces or other similar equipment;
  • In areas with a potentially explosive atmosphere;
  • In rooms with an aggressive atmosphere (which is e.g. caused by chemicals);
  • In rooms containing water with a pH value below 7.0 or above 7.4;
  • In areas with salt or liquids with a salt content > 1% e.g. salt baths;
  • In humid areas of indoor swimming pools;
  • In rooms with ozone-treated air, high solvent concentrations or high dust pollution.

Related products

  • General accessories

    View the range of general accessories here
    Extra gegevens

    View the range of general accessories here:

    ItemSizesSuitable for suction sideSuitable for press silk
    Connection socket for connecting attachments100 to 800 mmJJ
    Coupling bush for connecting pipes100 to 800 mmJJ
    T-piece100 to 800 mmJJ
    Y piece100 to 800 mmJJ
    Y-piece flexible130 to 600 mmNJ
    Flange edge100 to 800 mmJJ
    Control valve100 to 800 mmJJ
    45° bend100 to 800 mmJJ
    90° bend100 to 800 mmJJ
    Expiry100 to 600 mmJJ
    Very flexiblefrom 300mmNJ
    Filter cartridges100 to 600 mmJJ
    Clamp Band80 to 800 mmn/an/a
  • Extension cables

    View the range of extension cables here.
    Extra gegevens
    Extension cablesConnection voltagePlugLengthDiameterATEX zone
    Default230V230V / 16ACEE 7/7 type E/F25m3*2.5mm²n/a
    230V230V / 16A230 V / 16 A – 3 pole15m3*2.5mm²n/a
    400V400V / 16A400 V / 16 A – 5 pin25m5*2.5mm²n/a
    400V400V / 32A400 V / 32 A – 5 pin25m5*6mm²n/a
    400V400V / 63A400 V / 63 A – 5 pin25m5*16mm²n/a
    400V400V / 125A400 V / 125 A – 5 pin25m5*35mm²n/a
    ATEX42V42V / 16AATX 42V / 16A – 3 pin25m3*2.5mm²zone 1 and 21
    230V230V / 16ACEAG 230 V / 16 A – 3 poles25m3*2.5mm²zone 1 and 21
    400V400V / 16ACEAG 400 V / 16 A – 3 poles25m5*2.5mm²zone 1 and 21
    400V400V / 32ACEAG 400 V / 32 A – 5 pin25m5*6mm²zone 1 and 21
    400V400V / 63ACEAG 400 V / 63 A – 5 pin25m5*16mm²zone 1 and 21
  • Extra gegevens

    Isolated300mm / 12in6m20°C / + 120°CN0-2,500

    ApplicationDiameterLengthTemperature rangeATEXPressure Range
    Default80mm / 3in6m-20°C / +100°CN0-2,500 Pa
    Default100mm / 4in6m-20°C / +100°CN0-2,500 Pa
    Default125mm / 5in6m-20°C / +100°CN0-2,500 Pa
    Default160mm / 6in6m-20°C / +100°CN0-2,500 Pa
    Default200mm / 8in10m-20°C / +100°CN0-2,500 Pa
    Default250mm / 10in10m-20°C / +100°CN0-2,500 Pa
    Default300mm / 12in10m-20°C / +100°CN0-2,500 Pa
    Default350mm / 14in10m-20°C / +100°CN0-2,500 Pa
    Default400mm / 16in10m-20°C / +100°CN0-2,500 Pa
    Default450mm / 18in10m-20°C / +100°CN0-2,500 Pa
    Default500mm / 20in10m-20°C / +100°CN0-2,500 Pa
    Default550mm / 22in10m-20°C / +100°CN0-2,500 Pa
    Default600mm / 24in10m-20°C / +100°CN0-2,500 Pa
    Default800mm / 32in10m-20°C / +100°CN0-2,500 Pa
    Isolated450mm / 18in6m-20°C / +120°CN<0 – 2,500
    Isolated600mm / 24in6m-20°C / +120°CN<0 – 2,500
    Isolated500mm / 20in10m-20°C / +120°CN<0 – 2,500
    Isolated600mm / 24in10m-20°C / +120°CN<0 – 2,500
    Antistatic (ATEX)200mm / 8in5m – 10m-20°C / +100°CJVacuum: 4,000 Pa / Pressure: 14 kPa
    Antistatic (ATEX)250mm / 10in5m – 10m-20°C / +100°CJVacuum: 4,000 Pa / Pressure: 14 kPa
    Antistatic (ATEX)300mm / 12in5m – 10m-20°C / +100°CJVacuum: 4,000 Pa / Pressure: 14 kPa
    Antistatic (ATEX)400mm / 16in5m-20°C / +100°CJVacuum: 4,000 Pa / Pressure: 14 kPa
    Antistatic (ATEX)450mm / 18in5m – 10m-20°C / +100°CJVacuum: 4,000 Pa / Pressure: 14 kPa
    Antistatic (ATEX)500mm / 20in5m – 10m-20°C / +100°CJVacuum: 4,000 Pa / Pressure: 14 kPa
    Antistatic (ATEX)600mm / 24in5m – 10m-20°C / +100°CJVacuum: 4,000 Pa / Pressure: 14 kPa
    Air distribution hose300mm / 12in5m – 10m-20°C / +100°CN0 – 1,500 Pa
    Air distribution hose400mm / 16in5m – 10m-20°C / +100°CN0 – 1,500 Pa