CSRental

Adsorption dryer TTR-2800

The adsorption dryer TTR-2800 is equipped with technology according to the highest industrial requirements. This dryer is…

Featured specs
Amount of dry air (nominal) 2,800 m³/h at 300 Pa.
Reactivation air volume 570 m³/h at 300 Pa

Category:

Description

The TTR-2800 adsorption dryer is suitable for a wide variety of tasks such as room air dehumidification and process drying within industry, logistics or utilities.

The unit can operate in recirculation mode, and is especially suitable for low temperature and low humidity operation.

For temporary climate solutions for business, industry, construction and ATEX environments, you have come to the right place at CSrental B.V.

CSrental B.V. has professional advisors who will work with you to find the best rental solution for your business.

Call or e-mail us for a tailor-made quotation.

Minimum rental period: 7 days

Amount of dry air (nominal) 2,800 m³/h, at 300 Pa

Regeneration air volume 570 m³/h, at 300 Pa

Dehumidification capacity at 20 °C / 60% R.H. 376.4 kg / 24 h

Input power 21.6 kW / 31.7 A

Plug connection 400V / 32A – 5 pin

Connection voltage 400V / 50 Hz

Hygrostat optional

Noise level 70 dB(A)

Mobility forklift

Dimensions L x W x H1,348 x 769 x 1,323 mm excl. frame

Weight 250 kg excl. frame kg

Process air hose connection 315 mm

Regeneration air hose connection 200 mm

Warning:

In polluted environments where the adsorption dryer is active, it is essential to change the filters regularly. This ensures that the adsorption dryer continues to function optimally.

Before commissioning the adsorption dryer, survey the room and take any measures where necessary. The adsorption dryer must not be used in:

  • Environments where particles, gas, smoke and the like may be sucked in due to negative pressure created, which may adversely affect chimneys, furnaces or other similar equipment;
  • In areas with a potentially explosive atmosphere;
  • In rooms with an aggressive atmosphere (which is e.g. caused by chemicals);
  • In rooms containing water with a pH value below 7.0 or above 7.4;
  • In areas with salt or liquids with a salt content > 1% e.g. salt baths;
  • In humid areas of indoor swimming pools;
  • In rooms with ozone-treated air, high solvent concentrations or high dust pollution.

Related products

  • Extra gegevens

    Isolated300mm / 12in6m20°C / + 120°CN0-2,500

    Application Diameter Length Temperature range ATEX Pressure Range
    Default 80mm / 3in 6m -20°C / +100°C N 0-2,500 Pa
    Default 100mm / 4in 6m -20°C / +100°C N 0-2,500 Pa
    Default 125mm / 5in 6m -20°C / +100°C N 0-2,500 Pa
    Default 160mm / 6in 6m -20°C / +100°C N 0-2,500 Pa
    Default 200mm / 8in 10m -20°C / +100°C N 0-2,500 Pa
    Default 250mm / 10in 10m -20°C / +100°C N 0-2,500 Pa
    Default 300mm / 12in 10m -20°C / +100°C N 0-2,500 Pa
    Default 350mm / 14in 10m -20°C / +100°C N 0-2,500 Pa
    Default 400mm / 16in 10m -20°C / +100°C N 0-2,500 Pa
    Default 450mm / 18in 10m -20°C / +100°C N 0-2,500 Pa
    Default 500mm / 20in 10m -20°C / +100°C N 0-2,500 Pa
    Default 550mm / 22in 10m -20°C / +100°C N 0-2,500 Pa
    Default 600mm / 24in 10m -20°C / +100°C N 0-2,500 Pa
    Default 800mm / 32in 10m -20°C / +100°C N 0-2,500 Pa
    Isolated 450mm / 18in 6m -20°C / +120°C N <0 – 2,500
    Isolated 600mm / 24in 6m -20°C / +120°C N <0 – 2,500
    Isolated 500mm / 20in 10m -20°C / +120°C N <0 – 2,500
    Isolated 600mm / 24in 10m -20°C / +120°C N <0 – 2,500
    Antistatic (ATEX) 200mm / 8in 5m – 10m -20°C / +100°C J Vacuum: 4,000 Pa / Pressure: 14 kPa
    Antistatic (ATEX) 250mm / 10in 5m – 10m -20°C / +100°C J Vacuum: 4,000 Pa / Pressure: 14 kPa
    Antistatic (ATEX) 300mm / 12in 5m – 10m -20°C / +100°C J Vacuum: 4,000 Pa / Pressure: 14 kPa
    Antistatic (ATEX) 400mm / 16in 5m -20°C / +100°C J Vacuum: 4,000 Pa / Pressure: 14 kPa
    Antistatic (ATEX) 450mm / 18in 5m – 10m -20°C / +100°C J Vacuum: 4,000 Pa / Pressure: 14 kPa
    Antistatic (ATEX) 500mm / 20in 5m – 10m -20°C / +100°C J Vacuum: 4,000 Pa / Pressure: 14 kPa
    Antistatic (ATEX) 600mm / 24in 5m – 10m -20°C / +100°C J Vacuum: 4,000 Pa / Pressure: 14 kPa
    Air distribution hose 300mm / 12in 5m – 10m -20°C / +100°C N 0 – 1,500 Pa
    Air distribution hose 400mm / 16in 5m – 10m -20°C / +100°C N 0 – 1,500 Pa
    Air distribution hose 500mm / 20in 5m – 10m -20°C / +100°C N 0 – 1,500 Pa
  • Extension cables

    View the range of extension cables here.
    Extra gegevens
    Extension cables Connection voltage Plug Length Diameter ATEX zone
    Default 230V 230V / 16A CEE 7/7 type E/F 25m 3*2.5mm² n/a
    230V 230V / 16A 230 V / 16 A – 3 pole 15m 3*2.5mm² n/a
    400V 400V / 16A 400 V / 16 A – 5 pin 25m 5*2.5mm² n/a
    400V 400V / 32A 400 V / 32 A – 5 pin 25m 5*6mm² n/a
    400V 400V / 63A 400 V / 63 A – 5 pin 25m 5*16mm² n/a
    400V 400V / 125A 400 V / 125 A – 5 pin 25m 5*35mm² n/a
    ATEX 42V 42V / 16A ATX 42V / 16A – 3 pin 25m 3*2.5mm² zone 1 and 21
    230V 230V / 16A CEAG 230 V / 16 A – 3 poles 25m 3*2.5mm² zone 1 and 21
    400V 400V / 16A CEAG 400 V / 16 A – 3 poles 25m 5*2.5mm² zone 1 and 21
    400V 400V / 32A CEAG 400 V / 32 A – 5 pin 25m 5*6mm² zone 1 and 21
    400V 400V / 63A CEAG 400 V / 63 A – 5 pin 25m 5*16mm² zone 1 and 21
  • General accessories

    View the range of general accessories here
    Extra gegevens

    View the range of general accessories here:

    Item Sizes Suitable for suction side Suitable for press silk
    Connection socket for connecting attachments 100 to 800 mm J J
    Coupling bush for connecting pipes 100 to 800 mm J J
    T-piece 100 to 800 mm J J
    Y piece 100 to 800 mm J J
    Y-piece flexible 130 to 600 mm N J
    Flange edge 100 to 800 mm J J
    Control valve 100 to 800 mm J J
    45° bend 100 to 800 mm J J
    90° bend 100 to 800 mm J J
    Expiry 100 to 600 mm J J
    Very flexible from 300mm N J
    Filter cartridges 100 to 600 mm J J
    Clamp Band 80 to 800 mm n/a n/a