CSRental

Electric heater CEH 200

The Electric heater CEH 200 is a robust heater and has a heating capacity of 40 kW. By means of…

Featured specs
Capacity 40 kW (34,394 kcal)
Air displacement 3,000 m³/h

Category:

Description

The electric heater CEH 200 is a robust heater and has a heating capacity of 40 kW. The heater has 2 heating settings, namely 20 kW and 40 kW.
The CEH 200 is very easy to operate. Due to the powerful high-pressure fan, the warm air can be transported over a length of 20 meters from the stove.

For temporary climate solutions for business, industry, construction and ATEX environments, CSrental B.V. is the place to be.
CSrental B.V. has professional consultants who can work with you to find the best rental solution for your business.
Call or email us for a customized quote.

Minimum rental period: 7 days

Capacity20 kW / 40 kW (34,482 kcal)

Air displacement 3,000 m³/h

Power consumption 40 kW / 57 A

Connection voltage400V / 50 Hz

Plug connection 400 V / 63 A – 5 pin

Dimensions L x W x H 1,300 x 740 x 1,050 mm

Weight 105 kg

Air hose connectionø 500 or ø 600 mm

Fanradial

Number of positions 2

Thermostat no

Mobility mobile / forklift

Related products

  • Extra gegevens

    Isolated300mm / 12in6m20°C / + 120°CN0-2,500

    ApplicationDiameterLengthTemperature rangeATEXPressure Range
    Default80mm / 3in6m-20°C / +100°CN0-2,500 Pa
    Default100mm / 4in6m-20°C / +100°CN0-2,500 Pa
    Default125mm / 5in6m-20°C / +100°CN0-2,500 Pa
    Default160mm / 6in6m-20°C / +100°CN0-2,500 Pa
    Default200mm / 8in10m-20°C / +100°CN0-2,500 Pa
    Default250mm / 10in10m-20°C / +100°CN0-2,500 Pa
    Default300mm / 12in10m-20°C / +100°CN0-2,500 Pa
    Default350mm / 14in10m-20°C / +100°CN0-2,500 Pa
    Default400mm / 16in10m-20°C / +100°CN0-2,500 Pa
    Default450mm / 18in10m-20°C / +100°CN0-2,500 Pa
    Default500mm / 20in10m-20°C / +100°CN0-2,500 Pa
    Default550mm / 22in10m-20°C / +100°CN0-2,500 Pa
    Default600mm / 24in10m-20°C / +100°CN0-2,500 Pa
    Default800mm / 32in10m-20°C / +100°CN0-2,500 Pa
    Isolated450mm / 18in6m-20°C / +120°CN<0 – 2,500
    Isolated600mm / 24in6m-20°C / +120°CN<0 – 2,500
    Isolated500mm / 20in10m-20°C / +120°CN<0 – 2,500
    Isolated600mm / 24in10m-20°C / +120°CN<0 – 2,500
    Antistatic (ATEX)200mm / 8in5m – 10m-20°C / +100°CJVacuum: 4,000 Pa / Pressure: 14 kPa
    Antistatic (ATEX)250mm / 10in5m – 10m-20°C / +100°CJVacuum: 4,000 Pa / Pressure: 14 kPa
    Antistatic (ATEX)300mm / 12in5m – 10m-20°C / +100°CJVacuum: 4,000 Pa / Pressure: 14 kPa
    Antistatic (ATEX)400mm / 16in5m-20°C / +100°CJVacuum: 4,000 Pa / Pressure: 14 kPa
    Antistatic (ATEX)450mm / 18in5m – 10m-20°C / +100°CJVacuum: 4,000 Pa / Pressure: 14 kPa
    Antistatic (ATEX)500mm / 20in5m – 10m-20°C / +100°CJVacuum: 4,000 Pa / Pressure: 14 kPa
    Antistatic (ATEX)600mm / 24in5m – 10m-20°C / +100°CJVacuum: 4,000 Pa / Pressure: 14 kPa
    Air distribution hose300mm / 12in5m – 10m-20°C / +100°CN0 – 1,500 Pa
    Air distribution hose400mm / 16in5m – 10m-20°C / +100°CN0 – 1,500 Pa
    Air distribution hose500mm / 20in5m – 10m-20°C / +100°CN0 – 1,500 Pa
  • Extension cables

    View the range of extension cables here.
    Extra gegevens
    Extension cablesConnection voltagePlugLengthDiameterATEX zone
    Default230V230V / 16ACEE 7/7 type E/F25m3*2.5mm²n/a
    230V230V / 16A230 V / 16 A – 3 pole15m3*2.5mm²n/a
    400V400V / 16A400 V / 16 A – 5 pin25m5*2.5mm²n/a
    400V400V / 32A400 V / 32 A – 5 pin25m5*6mm²n/a
    400V400V / 63A400 V / 63 A – 5 pin25m5*16mm²n/a
    400V400V / 125A400 V / 125 A – 5 pin25m5*35mm²n/a
    ATEX42V42V / 16AATX 42V / 16A – 3 pin25m3*2.5mm²zone 1 and 21
    230V230V / 16ACEAG 230 V / 16 A – 3 poles25m3*2.5mm²zone 1 and 21
    400V400V / 16ACEAG 400 V / 16 A – 3 poles25m5*2.5mm²zone 1 and 21
    400V400V / 32ACEAG 400 V / 32 A – 5 pin25m5*6mm²zone 1 and 21
    400V400V / 63ACEAG 400 V / 63 A – 5 pin25m5*16mm²zone 1 and 21
  • Meter climate control

    View the range of meters for climate control here.
    Extra gegevens

    View the range of meters for controlling machines below.

    Atex thermostaat
    ATEX thermostat
    II 2G IIC T4 – II 2D IIIC T130
    CO² regulationData loggerDew point controlDigital thermostat and hygrostatDifferential pressure gauge
    TypethermostatCO² protectiondelete receiveddehumidificationthermostat and hygrostatventilation
    Control oftemperatureair qualitymonitoringdew point monitoringtemperature and humidityair volume
    Deployment areaHeatingventilationheating, cooling, dehumidification and humidificationdehumidifiersheating, cooling, dehumidification and humidificationoperational reliability ventilation
    Measure value-40 – +40 °C0 – 2,000ppm0 – 100 % RH
    -40 – 70+ °C
    0 – 100% RH0 – 100 % RH
    -20 – 80+ °C
    0 – 500 Pa
    Accuracy2% +/-2% +/-2% +/-2% +/-1.5% +/-2% +/-
    Switching range2.5A / 230V230 VBattery 3.6V2 A / 230 V2 A / 230 V2 A / 230 V
    Hygrostaat adsorptiedroger
    Hygrostat
    Suitable for MDC adsorption dryers
    Plug-in humidistat
    Suitable for 230 V dryers
    Plug thermostat
    Suitable for 230 V heaters
    Thermostat
    Suitable for the DFE 65 and 95
    Thermostat
    Suitable for the DFE 80 T
    Thermostat oil heaters
    Typehumidistatplug hygrostatplug thermostatthermostatthermostatthermostat
    Control ofhumidityhumiditytemperaturetemperaturetemperaturetemperature
    Deployment areadehumidification and humidificationdehumidification and humidificationheatingheatingheatingheating
    Measure value30 – 100% RH10 – 90 % RH0 – 60% RH0 – 40% RH0 – 40% RH0 – 40% RH
    Accuracy3% +/-5% +/-5% +/-3% +/-3% +/-3% +/-
    Switching range5 A / 230 V
    2 A / 230 V
    2 A / 230 V2 A / 230 V25 A / 400 V2 A / 230 V2 A / 230 V
  • CTM Monitoring

    CTM monitoring is a climate monitoring system.Featured specs: 230V - Humidity-, Temperature-, CO² Measuring....
    Extra gegevens

    How does CTM climate monitoring work?

    CTM monitoring works by means of a GPS signal. The monitoring is equipped with a 230V connection. The system consists of wirelessly coupled sensor modules. The data collected by these sensors are sent to a portal and are only visible to you, the customer. In the portal, these sensor modules can also be set up.

    There are various sensors, these sensors are used to measure various quantities and units. These include:

    • Temperature;
    • Relative humidity;
    • Pressure (difference);
    • Carbon dioxide.

    The user-friendly portal of the CTM monitoring system makes monitoring easy. In the portal, measured data are visualised and compared with pre-set limit values.
    When values are exceeded, an alarm that can be received by e-mail or SMS follows. The advantage of the CTM system is that measurement results can be analysed directly online. With one system; spraying and blasting operations, storage areas, cold stores and freezers, ect. are monitored.
    Once the process is complete, all data can be downloaded as a PDF file. If necessary, this can be added to files as evidence.

  • General accessories

    View the range of general accessories here
    Extra gegevens

    View the range of general accessories here:

    ItemSizesSuitable for suction sideSuitable for press silk
    Connection socket for connecting attachments100 to 800 mmJJ
    Coupling bush for connecting pipes100 to 800 mmJJ
    T-piece100 to 800 mmJJ
    Y piece100 to 800 mmJJ
    Y-piece flexible130 to 600 mmNJ
    Flange edge100 to 800 mmJJ
    Control valve100 to 800 mmJJ
    45° bend100 to 800 mmJJ
    90° bend100 to 800 mmJJ
    Expiry100 to 600 mmJJ
    Very flexiblefrom 300mmNJ
    Filter cartridges100 to 600 mmJJ
    Clamp Band80 to 800 mmn/an/a