Capacity 110 kW (94,828 kcal)
Fuel consumption max. 10.9 (l/h)
Air displacement 10,000 m³/h

Description

The Oil fired heater ID-800M (also known as IMA111RHP) is a mobile, indirectly fired diesel heater, equipped with an EC high-pressure fan, a soft starter and automatic phase recognition.
As a result, the machine can be installed quickly and several air transport hoses can be placed without any problems.

The EC motor and automatic burner control with thermostat connection ensure that the machine does not consume more energy than strictly necessary.

Thanks to the intercal industrial burner with flow control, the stove supplies 110 kW of clean warm air with a delta ΔT of approx. 47°C.
The burner chamber is heat resistant up to 850°C and is a high efficiency heat exchanger (92%).

There is a possibility to connect hoses through the 500 mm hose connection. This makes it possible to target heating.

Please note that there must be sufficient room ventilation during use and when you connect air transport hoses, they must be suitable for use at high temperatures.

For temporary climate solutions for business, industry, construction and ATEX environments, CSrental B.V. is the place to be.
CSrental B.V. has professional consultants who can work with you to find the best rental solution for your business.
Call or email us for a customized quote.

Minimum rental 7 days

Capacity110 kW (94,828 kcal)

Fuel consumption max.10.9 (l/h)

Air displacement 10,000 m³/h

Max. back pressure fan 500 Pa

Power consumption 3 kW / 7.5 A

Connection voltage400 V / 50 Hz

Plug connection 400 V – 16 A / 5 pin or 32 A / 5 pin

Dimensions L x W x H 2,230 x 780 x 1,340 mm

Weight 340 kg

Discharge cone Ø 500 mm / 4 x 300 mm

Chimney connection Ø 200 mm

Hose length per connectionClick here for the overview

Thermostat connection Yes

Applications

Agriculture:
– heating workspace and storage sheds;
– drying agricultural products and bulbs to prevent harmful ethylene formation.

Horticulture:
– Heating greenhouses and polytunnels without the risk of harmful CO2 and CO emissions;
– Heating of industrial sorting areas;
– Heating halls and storage sheds, defrosting pipes and installations.

Build:
– Heating and drying of construction sites and construction projects;
– Drying of buildings after flooding.

Events:
– ID 800 M is particularly suitable for heating tents and showrooms.

Related products

  • Spark arrestor

    View the range of the different variants of flue gas discharge here.
  • Extension cables

    View the range of extension cables here.
    Extra gegevens
    Extension cablesConnection voltagePlugLengthDiameterATEX zone
    Default230V230V / 16ACEE 7/7 type E/F25m3*2.5mm²n/a
    230V230V / 16A230 V / 16 A – 3 pole15m3*2.5mm²n/a
    400V400V / 16A400 V / 16 A – 5 pin25m5*2.5mm²n/a
    400V400V / 32A400 V / 32 A – 5 pin25m5*6mm²n/a
    400V400V / 63A400 V / 63 A – 5 pin25m5*16mm²n/a
    400V400V / 125A400 V / 125 A – 5 pin25m5*35mm²n/a
    ATEX42V42V / 16AATX 42V / 16A – 3 pin25m3*2.5mm²zone 1 and 21
    230V230V / 16ACEAG 230 V / 16 A – 3 poles25m3*2.5mm²zone 1 and 21
    400V400V / 16ACEAG 400 V / 16 A – 3 poles25m5*2.5mm²zone 1 and 21
    400V400V / 32ACEAG 400 V / 32 A – 5 pin25m5*6mm²zone 1 and 21
    400V400V / 63ACEAG 400 V / 63 A – 5 pin25m5*16mm²zone 1 and 21
  • Meter climate control

    View the range of meters for climate control here.
    Extra gegevens

    View the range of meters for controlling machines below.

    Atex thermostaat
    ATEX thermostat
    II 2G IIC T4 – II 2D IIIC T130
    CO² regulationData loggerDew point controlDigital thermostat and hygrostatDifferential pressure gauge
    TypethermostatCO² protectiondelete receiveddehumidificationthermostat and hygrostatventilation
    Control oftemperatureair qualitymonitoringdew point monitoringtemperature and humidityair volume
    Deployment areaHeatingventilationheating, cooling, dehumidification and humidificationdehumidifiersheating, cooling, dehumidification and humidificationoperational reliability ventilation
    Measure value-40 – +40 °C0 – 2,000ppm0 – 100 % RH
    -40 – 70+ °C
    0 – 100% RH0 – 100 % RH
    -20 – 80+ °C
    0 – 500 Pa
    Accuracy2% +/-2% +/-2% +/-2% +/-1.5% +/-2% +/-
    Switching range2.5A / 230V230 VBattery 3.6V2 A / 230 V2 A / 230 V2 A / 230 V
    Hygrostaat adsorptiedroger
    Hygrostat
    Suitable for MDC adsorption dryers
    Plug-in humidistat
    Suitable for 230 V dryers
    Plug thermostat
    Suitable for 230 V heaters
    Thermostat
    Suitable for the DFE 65 and 95
    Thermostat
    Suitable for the DFE 80 T
    Thermostat oil heaters
    Typehumidistatplug hygrostatplug thermostatthermostatthermostatthermostat
    Control ofhumidityhumiditytemperaturetemperaturetemperaturetemperature
    Deployment areadehumidification and humidificationdehumidification and humidificationheatingheatingheatingheating
    Measure value30 – 100% RH10 – 90 % RH0 – 60% RH0 – 40% RH0 – 40% RH0 – 40% RH
    Accuracy3% +/-5% +/-5% +/-3% +/-3% +/-3% +/-
    Switching range5 A / 230 V
    2 A / 230 V
    2 A / 230 V2 A / 230 V25 A / 400 V2 A / 230 V2 A / 230 V
  • Hose manifold oil heaters

    View the hose distributors for the oil-fired heaters here.
  • Extra gegevens

    Isolated300mm / 12in6m20°C / + 120°CN0-2,500

    ApplicationDiameterLengthTemperature rangeATEXPressure Range
    Default80mm / 3in6m-20°C / +100°CN0-2,500 Pa
    Default100mm / 4in6m-20°C / +100°CN0-2,500 Pa
    Default125mm / 5in6m-20°C / +100°CN0-2,500 Pa
    Default160mm / 6in6m-20°C / +100°CN0-2,500 Pa
    Default200mm / 8in10m-20°C / +100°CN0-2,500 Pa
    Default250mm / 10in10m-20°C / +100°CN0-2,500 Pa
    Default300mm / 12in10m-20°C / +100°CN0-2,500 Pa
    Default350mm / 14in10m-20°C / +100°CN0-2,500 Pa
    Default400mm / 16in10m-20°C / +100°CN0-2,500 Pa
    Default450mm / 18in10m-20°C / +100°CN0-2,500 Pa
    Default500mm / 20in10m-20°C / +100°CN0-2,500 Pa
    Default550mm / 22in10m-20°C / +100°CN0-2,500 Pa
    Default600mm / 24in10m-20°C / +100°CN0-2,500 Pa
    Default800mm / 32in10m-20°C / +100°CN0-2,500 Pa
    Isolated450mm / 18in6m-20°C / +120°CN<0 – 2,500
    Isolated600mm / 24in6m-20°C / +120°CN<0 – 2,500
    Isolated500mm / 20in10m-20°C / +120°CN<0 – 2,500
    Isolated600mm / 24in10m-20°C / +120°CN<0 – 2,500
    Antistatic (ATEX)200mm / 8in5m – 10m-20°C / +100°CJVacuum: 4,000 Pa / Pressure: 14 kPa
    Antistatic (ATEX)250mm / 10in5m – 10m-20°C / +100°CJVacuum: 4,000 Pa / Pressure: 14 kPa
    Antistatic (ATEX)300mm / 12in5m – 10m-20°C / +100°CJVacuum: 4,000 Pa / Pressure: 14 kPa
    Antistatic (ATEX)400mm / 16in5m-20°C / +100°CJVacuum: 4,000 Pa / Pressure: 14 kPa
    Antistatic (ATEX)450mm / 18in5m – 10m-20°C / +100°CJVacuum: 4,000 Pa / Pressure: 14 kPa
    Antistatic (ATEX)500mm / 20in5m – 10m-20°C / +100°CJVacuum: 4,000 Pa / Pressure: 14 kPa
    Antistatic (ATEX)600mm / 24in5m – 10m-20°C / +100°CJVacuum: 4,000 Pa / Pressure: 14 kPa
    Air distribution hose300mm / 12in5m – 10m-20°C / +100°CN0 – 1,500 Pa
    Air distribution hose400mm / 16in5m – 10m-20°C / +100°CN0 – 1,500 Pa
    Air distribution hose500mm / 20in5m – 10m-20°C / +100°CN0 – 1,500 Pa
  • (flexbile) Chimney

    View the range of the different variants of flue gas discharge here.
  • General accessories

    View the range of general accessories here
    Extra gegevens

    View the range of general accessories here:

    ItemSizesSuitable for suction sideSuitable for press silk
    Connection socket for connecting attachments100 to 800 mmJJ
    Coupling bush for connecting pipes100 to 800 mmJJ
    T-piece100 to 800 mmJJ
    Y piece100 to 800 mmJJ
    Y-piece flexible130 to 600 mmNJ
    Flange edge100 to 800 mmJJ
    Control valve100 to 800 mmJJ
    45° bend100 to 800 mmJJ
    90° bend100 to 800 mmJJ
    Expiry100 to 600 mmJJ
    Very flexiblefrom 300mmNJ
    Filter cartridges100 to 600 mmJJ
    Clamp Band80 to 800 mmn/an/a
  • Fuel tank