CSRental

Adsorption dryer MDC-450

The MDC-450 adsorption dryer is designed for general dehumidification such as room air drying and process drying…

Featured specs
Dry air volume (nominal) 450 m³/h at 50 Pa
Regeneration air 120m³/h at 50 Pa

Category:

Description

The MDC-450 adsorption dryer is designed for general dehumidification such as room air drying and process drying.

Due to its small size, this machine can be used in hard-to-reach places to work there for long periods of time with minimum maintenance. Its low weight of 24 kg makes this adsorption dryer easy to be moved by 1 person.

The MDC-450 adsorption dryer is designed for: drying buildings, dehumidifying room air, dry air storage, water works and pumping stations. Especially suitable for operation at low temperature and low desired humidity.

For temporary climate solutions for business, industry, construction and ATEX environments, you have come to the right place at CSrental B.V.

CSrental B.V. has professional advisors who will work with you to find the best rental solution for your business.

Call or e-mail us for a tailor-made quotation.

Minimum rental period: 7 days

Amount of dry air (nominal) 450 m³/h, at 120 Pa

Regeneration air volume 120 m³/h, at 50 Pa

Dehumidification capacity at 20 °C / 60% R.H. 52.8 kg / 24 h

Power input 3 kW / 13A

Plug connection CEE 7/7 type E/F

Connection voltage 230V / 50 Hz

Hygrostat optional

Noise level 62 dB(A)

Mobility moveable

Dimensions L x W x H680 x 430 x 515 mm

Weight 24 kg

Process air hose connection 160 mm

Regeneration air hose connection 80 mm

Warning:

In polluted environments where the adsorption dryer is active, it is essential to change the filters regularly. This ensures that the adsorption dryer continues to function optimally.

Before commissioning the adsorption dryer, survey the room and take any measures where necessary. The adsorption dryer must not be used in:

  • Environments where particles, gas, smoke and the like may be sucked in due to negative pressure created, which may adversely affect chimneys, furnaces or other similar equipment;
  • In areas with a potentially explosive atmosphere;
  • In rooms with an aggressive atmosphere (which is e.g. caused by chemicals);
  • In rooms containing water with a pH value below 7.0 or above 7.4;
  • In areas with salt or liquids with a salt content > 1% e.g. salt baths;
  • In humid areas of indoor swimming pools;
  • In rooms with ozone-treated air, high solvent concentrations or high dust pollution.

Related products

  • Meter climate control

    View the range of meters for climate control here.
    Extra gegevens

    View the range of meters for controlling machines below.

    Atex thermostaat
    ATEX thermostat
    II 2G IIC T4 – II 2D IIIC T130
    CO² regulationData loggerDew point controlDigital thermostat and hygrostatDifferential pressure gauge
    TypethermostatCO² protectiondelete receiveddehumidificationthermostat and hygrostatventilation
    Control oftemperatureair qualitymonitoringdew point monitoringtemperature and humidityair volume
    Deployment areaHeatingventilationheating, cooling, dehumidification and humidificationdehumidifiersheating, cooling, dehumidification and humidificationoperational reliability ventilation
    Measure value-40 – +40 °C0 – 2,000ppm0 – 100 % RH
    -40 – 70+ °C
    0 – 100% RH0 – 100 % RH
    -20 – 80+ °C
    0 – 500 Pa
    Accuracy2% +/-2% +/-2% +/-2% +/-1.5% +/-2% +/-
    Switching range2.5A / 230V230 VBattery 3.6V2 A / 230 V2 A / 230 V2 A / 230 V
    Hygrostaat adsorptiedroger
    Hygrostat
    Suitable for MDC adsorption dryers
    Plug-in humidistat
    Suitable for 230 V dryers
    Plug thermostat
    Suitable for 230 V heaters
    Thermostat
    Suitable for the DFE 65 and 95
    Thermostat
    Suitable for the DFE 80 T
    Thermostat oil heaters
    Typehumidistatplug hygrostatplug thermostatthermostatthermostatthermostat
    Control ofhumidityhumiditytemperaturetemperaturetemperaturetemperature
    Deployment areadehumidification and humidificationdehumidification and humidificationheatingheatingheatingheating
    Measure value30 – 100% RH10 – 90 % RH0 – 60% RH0 – 40% RH0 – 40% RH0 – 40% RH
    Accuracy3% +/-5% +/-5% +/-3% +/-3% +/-3% +/-
    Switching range5 A / 230 V
    2 A / 230 V
    2 A / 230 V2 A / 230 V25 A / 400 V2 A / 230 V2 A / 230 V
  • General accessories

    View the range of general accessories here
    Extra gegevens

    View the range of general accessories here:

    ItemSizesSuitable for suction sideSuitable for press silk
    Connection socket for connecting attachments100 to 800 mmJJ
    Coupling bush for connecting pipes100 to 800 mmJJ
    T-piece100 to 800 mmJJ
    Y piece100 to 800 mmJJ
    Y-piece flexible130 to 600 mmNJ
    Flange edge100 to 800 mmJJ
    Control valve100 to 800 mmJJ
    45° bend100 to 800 mmJJ
    90° bend100 to 800 mmJJ
    Expiry100 to 600 mmJJ
    Very flexiblefrom 300mmNJ
    Filter cartridges100 to 600 mmJJ
    Clamp Band80 to 800 mmn/an/a
  • Extra gegevens

    Isolated300mm / 12in6m20°C / + 120°CN0-2,500

    ApplicationDiameterLengthTemperature rangeATEXPressure Range
    Default80mm / 3in6m-20°C / +100°CN0-2,500 Pa
    Default100mm / 4in6m-20°C / +100°CN0-2,500 Pa
    Default125mm / 5in6m-20°C / +100°CN0-2,500 Pa
    Default160mm / 6in6m-20°C / +100°CN0-2,500 Pa
    Default200mm / 8in10m-20°C / +100°CN0-2,500 Pa
    Default250mm / 10in10m-20°C / +100°CN0-2,500 Pa
    Default300mm / 12in10m-20°C / +100°CN0-2,500 Pa
    Default350mm / 14in10m-20°C / +100°CN0-2,500 Pa
    Default400mm / 16in10m-20°C / +100°CN0-2,500 Pa
    Default450mm / 18in10m-20°C / +100°CN0-2,500 Pa
    Default500mm / 20in10m-20°C / +100°CN0-2,500 Pa
    Default550mm / 22in10m-20°C / +100°CN0-2,500 Pa
    Default600mm / 24in10m-20°C / +100°CN0-2,500 Pa
    Default800mm / 32in10m-20°C / +100°CN0-2,500 Pa
    Isolated450mm / 18in6m-20°C / +120°CN<0 – 2,500
    Isolated600mm / 24in6m-20°C / +120°CN<0 – 2,500
    Isolated500mm / 20in10m-20°C / +120°CN<0 – 2,500
    Isolated600mm / 24in10m-20°C / +120°CN<0 – 2,500
    Antistatic (ATEX)200mm / 8in5m – 10m-20°C / +100°CJVacuum: 4,000 Pa / Pressure: 14 kPa
    Antistatic (ATEX)250mm / 10in5m – 10m-20°C / +100°CJVacuum: 4,000 Pa / Pressure: 14 kPa
    Antistatic (ATEX)300mm / 12in5m – 10m-20°C / +100°CJVacuum: 4,000 Pa / Pressure: 14 kPa
    Antistatic (ATEX)400mm / 16in5m-20°C / +100°CJVacuum: 4,000 Pa / Pressure: 14 kPa
    Antistatic (ATEX)450mm / 18in5m – 10m-20°C / +100°CJVacuum: 4,000 Pa / Pressure: 14 kPa
    Antistatic (ATEX)500mm / 20in5m – 10m-20°C / +100°CJVacuum: 4,000 Pa / Pressure: 14 kPa
    Antistatic (ATEX)600mm / 24in5m – 10m-20°C / +100°CJVacuum: 4,000 Pa / Pressure: 14 kPa
    Air distribution hose300mm / 12in5m – 10m-20°C / +100°CN0 – 1,500 Pa
    Air distribution hose400mm / 16in5m – 10m-20°C / +100°CN0 – 1,500 Pa
    Air distribution hose500mm / 20in5m – 10m-20°C / +100°CN0 – 1,500 Pa
  • Extension cables

    View the range of extension cables here.
    Extra gegevens
    Extension cablesConnection voltagePlugLengthDiameterATEX zone
    Default230V230V / 16ACEE 7/7 type E/F25m3*2.5mm²n/a
    230V230V / 16A230 V / 16 A – 3 pole15m3*2.5mm²n/a
    400V400V / 16A400 V / 16 A – 5 pin25m5*2.5mm²n/a
    400V400V / 32A400 V / 32 A – 5 pin25m5*6mm²n/a
    400V400V / 63A400 V / 63 A – 5 pin25m5*16mm²n/a
    400V400V / 125A400 V / 125 A – 5 pin25m5*35mm²n/a
    ATEX42V42V / 16AATX 42V / 16A – 3 pin25m3*2.5mm²zone 1 and 21
    230V230V / 16ACEAG 230 V / 16 A – 3 poles25m3*2.5mm²zone 1 and 21
    400V400V / 16ACEAG 400 V / 16 A – 3 poles25m5*2.5mm²zone 1 and 21
    400V400V / 32ACEAG 400 V / 32 A – 5 pin25m5*6mm²zone 1 and 21
    400V400V / 63ACEAG 400 V / 63 A – 5 pin25m5*16mm²zone 1 and 21
  • CTM Monitoring

    CTM monitoring is a climate monitoring system.Featured specs: 230V - Humidity-, Temperature-, CO² Measuring....
    Extra gegevens

    How does CTM climate monitoring work?

    CTM monitoring works by means of a GPS signal. The monitoring is equipped with a 230V connection. The system consists of wirelessly coupled sensor modules. The data collected by these sensors are sent to a portal and are only visible to you, the customer. In the portal, these sensor modules can also be set up.

    There are various sensors, these sensors are used to measure various quantities and units. These include:

    • Temperature;
    • Relative humidity;
    • Pressure (difference);
    • Carbon dioxide.

    The user-friendly portal of the CTM monitoring system makes monitoring easy. In the portal, measured data are visualised and compared with pre-set limit values.
    When values are exceeded, an alarm that can be received by e-mail or SMS follows. The advantage of the CTM system is that measurement results can be analysed directly online. With one system; spraying and blasting operations, storage areas, cold stores and freezers, ect. are monitored.
    Once the process is complete, all data can be downloaded as a PDF file. If necessary, this can be added to files as evidence.