CSRental

Oil fired heater ID-300M

The Oil fired heater ID300M is an indirectly fired diesel heater, equipped with…

Featured specs
Capacity 45 kW (38,793 kcal)
Fuel consumption max. 4.5 (l/h)
Air displacement 3,000 m³/h

Description

The Oil fired heater ID-300M (also known as ITA 45 Robust) is an indirectly fired diesel heater, equipped with its own fuel tank of up to 80 litres. As a result, the machine can be installed quickly and without much installation work and can heat up to 16 hours at a time. The high-pressure pump is suitable for diesel and petroleum and the whole runs on a 1-way pipe, so there is less chance of malfunctions and leaks.

Through the flue gas outlet, the stove supplies 45 kW of clean warm air with a delta ΔT of 50°C. The burner chamber is heat resistant up to 850°C and is a high efficiency heat exchanger (91%).
There is a possibility to connect hoses through the optional hose adapter. This makes it possible to target heating.
The machine is equipped with a tank heater, so that the fuel is suitable for the burner even at very low temperatures.

Please note that there must be sufficient room ventilation during use and when you connect air transport hoses, they must be suitable for use at high temperatures.

For temporary climate solutions for business, industry, construction and ATEX environments, CSrental B.V. is the place to be.
CSrental B.V. has professional consultants who can work with you to find the best rental solution for your business.
Call or email us for a customized quote.

Minimum rental 7 days

Capacity 45 kW (38,793 kcal)

Fuel consumption max.4.5 (l/h)

Air displacement 3,000 m³/h

Max. back pressure fan 200 Pa

Power consumption 800 W / 3.3 A

Connection voltage230 V / 50 Hz

Plug connection CEE 7/7 type E/F

Fuel tank capacity 80 l

Dimensions L x W x H 1,680 x 690 x 940 mm

Weight 148 kg

Discharge cone Ø 400 mm / 2 x 200 mm

Chimney connection Ø 150 mm

Hose length per connectionClick here for the overview

Thermostat connectionYes

Applications

Agriculture:
– Heating of workspace and storage sheds;
– Drying of agricultural products and bulbs to prevent harmful ethylene formation.

Horticulture:
– Heating greenhouses and polytunnels without the risk of harmful CO2 and CO emissions;
– Heating of industrial sorting areas;
– Heating halls and storage sheds, defrosting pipes and installations.

Build:
– Heating and drying of construction sites and construction projects;
– Drying of buildings after flooding.

Events:
– ID300 M is particularly suitable for heating tents and showrooms.

Related products

  • Extra gegevens

    Isolated300mm / 12in6m20°C / + 120°CN0-2,500

    ApplicationDiameterLengthTemperature rangeATEXPressure Range
    Default80mm / 3in6m-20°C / +100°CN0-2,500 Pa
    Default100mm / 4in6m-20°C / +100°CN0-2,500 Pa
    Default125mm / 5in6m-20°C / +100°CN0-2,500 Pa
    Default160mm / 6in6m-20°C / +100°CN0-2,500 Pa
    Default200mm / 8in10m-20°C / +100°CN0-2,500 Pa
    Default250mm / 10in10m-20°C / +100°CN0-2,500 Pa
    Default300mm / 12in10m-20°C / +100°CN0-2,500 Pa
    Default350mm / 14in10m-20°C / +100°CN0-2,500 Pa
    Default400mm / 16in10m-20°C / +100°CN0-2,500 Pa
    Default450mm / 18in10m-20°C / +100°CN0-2,500 Pa
    Default500mm / 20in10m-20°C / +100°CN0-2,500 Pa
    Default550mm / 22in10m-20°C / +100°CN0-2,500 Pa
    Default600mm / 24in10m-20°C / +100°CN0-2,500 Pa
    Default800mm / 32in10m-20°C / +100°CN0-2,500 Pa
    Isolated450mm / 18in6m-20°C / +120°CN<0 – 2,500
    Isolated600mm / 24in6m-20°C / +120°CN<0 – 2,500
    Isolated500mm / 20in10m-20°C / +120°CN<0 – 2,500
    Isolated600mm / 24in10m-20°C / +120°CN<0 – 2,500
    Antistatic (ATEX)200mm / 8in5m – 10m-20°C / +100°CJVacuum: 4,000 Pa / Pressure: 14 kPa
    Antistatic (ATEX)250mm / 10in5m – 10m-20°C / +100°CJVacuum: 4,000 Pa / Pressure: 14 kPa
    Antistatic (ATEX)300mm / 12in5m – 10m-20°C / +100°CJVacuum: 4,000 Pa / Pressure: 14 kPa
    Antistatic (ATEX)400mm / 16in5m-20°C / +100°CJVacuum: 4,000 Pa / Pressure: 14 kPa
    Antistatic (ATEX)450mm / 18in5m – 10m-20°C / +100°CJVacuum: 4,000 Pa / Pressure: 14 kPa
    Antistatic (ATEX)500mm / 20in5m – 10m-20°C / +100°CJVacuum: 4,000 Pa / Pressure: 14 kPa
    Antistatic (ATEX)600mm / 24in5m – 10m-20°C / +100°CJVacuum: 4,000 Pa / Pressure: 14 kPa
    Air distribution hose300mm / 12in5m – 10m-20°C / +100°CN0 – 1,500 Pa
    Air distribution hose400mm / 16in5m – 10m-20°C / +100°CN0 – 1,500 Pa
    Air distribution hose500mm / 20in5m – 10m-20°C / +100°CN0 – 1,500 Pa
  • Extension cables

    View the range of extension cables here.
    Extra gegevens
    Extension cablesConnection voltagePlugLengthDiameterATEX zone
    Default230V230V / 16ACEE 7/7 type E/F25m3*2.5mm²n/a
    230V230V / 16A230 V / 16 A – 3 pole15m3*2.5mm²n/a
    400V400V / 16A400 V / 16 A – 5 pin25m5*2.5mm²n/a
    400V400V / 32A400 V / 32 A – 5 pin25m5*6mm²n/a
    400V400V / 63A400 V / 63 A – 5 pin25m5*16mm²n/a
    400V400V / 125A400 V / 125 A – 5 pin25m5*35mm²n/a
    ATEX42V42V / 16AATX 42V / 16A – 3 pin25m3*2.5mm²zone 1 and 21
    230V230V / 16ACEAG 230 V / 16 A – 3 poles25m3*2.5mm²zone 1 and 21
    400V400V / 16ACEAG 400 V / 16 A – 3 poles25m5*2.5mm²zone 1 and 21
    400V400V / 32ACEAG 400 V / 32 A – 5 pin25m5*6mm²zone 1 and 21
    400V400V / 63ACEAG 400 V / 63 A – 5 pin25m5*16mm²zone 1 and 21
  • Meter climate control

    View the range of meters for climate control here.
    Extra gegevens

    View the range of meters for controlling machines below.

    Atex thermostaat
    ATEX thermostat
    II 2G IIC T4 – II 2D IIIC T130
    CO² regulationData loggerDew point controlDigital thermostat and hygrostatDifferential pressure gauge
    TypethermostatCO² protectiondelete receiveddehumidificationthermostat and hygrostatventilation
    Control oftemperatureair qualitymonitoringdew point monitoringtemperature and humidityair volume
    Deployment areaHeatingventilationheating, cooling, dehumidification and humidificationdehumidifiersheating, cooling, dehumidification and humidificationoperational reliability ventilation
    Measure value-40 – +40 °C0 – 2,000ppm0 – 100 % RH
    -40 – 70+ °C
    0 – 100% RH0 – 100 % RH
    -20 – 80+ °C
    0 – 500 Pa
    Accuracy2% +/-2% +/-2% +/-2% +/-1.5% +/-2% +/-
    Switching range2.5A / 230V230 VBattery 3.6V2 A / 230 V2 A / 230 V2 A / 230 V
    Hygrostaat adsorptiedroger
    Hygrostat
    Suitable for MDC adsorption dryers
    Plug-in humidistat
    Suitable for 230 V dryers
    Plug thermostat
    Suitable for 230 V heaters
    Thermostat
    Suitable for the DFE 65 and 95
    Thermostat
    Suitable for the DFE 80 T
    Thermostat oil heaters
    Typehumidistatplug hygrostatplug thermostatthermostatthermostatthermostat
    Control ofhumidityhumiditytemperaturetemperaturetemperaturetemperature
    Deployment areadehumidification and humidificationdehumidification and humidificationheatingheatingheatingheating
    Measure value30 – 100% RH10 – 90 % RH0 – 60% RH0 – 40% RH0 – 40% RH0 – 40% RH
    Accuracy3% +/-5% +/-5% +/-3% +/-3% +/-3% +/-
    Switching range5 A / 230 V
    2 A / 230 V
    2 A / 230 V2 A / 230 V25 A / 400 V2 A / 230 V2 A / 230 V
  • (flexbile) Chimney

    View the range of the different variants of flue gas discharge here.
  • Hose manifold oil heaters

    View the hose distributors for the oil-fired heaters here.
  • General accessories

    View the range of general accessories here
    Extra gegevens

    View the range of general accessories here:

    ItemSizesSuitable for suction sideSuitable for press silk
    Connection socket for connecting attachments100 to 800 mmJJ
    Coupling bush for connecting pipes100 to 800 mmJJ
    T-piece100 to 800 mmJJ
    Y piece100 to 800 mmJJ
    Y-piece flexible130 to 600 mmNJ
    Flange edge100 to 800 mmJJ
    Control valve100 to 800 mmJJ
    45° bend100 to 800 mmJJ
    90° bend100 to 800 mmJJ
    Expiry100 to 600 mmJJ
    Very flexiblefrom 300mmNJ
    Filter cartridges100 to 600 mmJJ
    Clamp Band80 to 800 mmn/an/a