CSRental

Chiller CSC-5

CSrental’s Chiller CSC-5 is equipped with technology that ensures maximum…

Featured specs
Connection voltage 230V / 50Hz
Cooling capacity max. 5.5 kW

Category:

Description

The Chiller CSC-5 from CSrental is equipped with environmentally friendly technology that ensures maximum efficiency with minimal electricity consumption and meets the latest technical requirements. By means of pipes and accessories, the CSC chiller can be connected to almost any existing system or process.

The Chiller CSC-5 is standard equipped with a pump and buffer vessel so that installation can be done quickly and easily. Chillers are often used as process coolers or for planned maintenance of existing chillers/coolers.

For temporary climate solutions for business, industry, construction and ATEX environments, CSrental B.V. is the place to be.
CSrental B.V. has professional consultants who can work with you to find the best rental solution for your business.
Call or email us for a customized quote.

Minimum rental period: 7 days

Cooling capacity max. 5.5 kW / +12/7°C

Air flow rate1.500 m³/h

Water flow 0.9 m³/h

Available pressure 252 kPa

Tank capacity 40 L

Coupling 1” Geka

Max. power consumption13 A

Power consumption 2.5 kW

Connection voltage 230V / 50Hz

IP class 54

Noise level 51 dB(A) (at 10 m)

Dimensions L x W x H 700 mm x 600 mm x 960 mm

Weight 90 kg excluding liquids

Mobility Forklift

Water quality requirements

When using water as a secondary fluid, the quality of the water must meet the requirements specified in the table below.

Parameter Value
pH Between 7 – 9
Electrical conductivity 100 – 700 µS/cm
Solphates SO4- < 100 mg/l
Bicarbonate HCO3- < 200 mg/l
Cloride C1- < 50 mg/l
Phosphate PO4 3- < 2 mg/l
Carbon dioxide CO² < 5 mg/l
Oxigen O2 < 0,1 mg/l
Nitrates NO3- < 5 mg/l
Ammonia NH3 Absent
Hydrogen sulfide H2S Absent
Chlorite Absent
Free chlorine < 0,2 mg/l

The following liquids are strictly prohibited:
– Demineralised water;
– Distilled water;
– Sea water;
– Other liquids that differ from the standard Ethylene/Propylene glycol.

Related products

  • Distributors with camlock coupling

    On the camlock coupling it is possible to place an adapter to a Geka coupling
  • Camlock pressure regulator

    The pressure regulator with camlock connection is available in 1¼” and 2″.
  • Hose connections

    View the range of connecting hoses here.
    Extra gegevens
    Connecting hose Application Link Length
    Air conditioning 3/8 flat face 5m
    3/8 flat face 10m
    3/8 flat face 15m
    Chillers / Boilers 1¼” cam lock 5m
    1¼” cam lock 10m
    2″ cam lock 3m
    2″ cam lock 5m
    2″ cam lock 10m
    Electric water heater 1″ geka 5m
    Underfloor heating 1″geka 10m
    Heating diesel heaters 3/8 flat face 5m
    3/8 flat face 10m
    Compressed air ludecke 10m
    Claw coupling ludecke adjustable 10m
    Common links: Bauwer, boilers Storz coupling, fire brigade Perrot coupling, agriculture
  • Flange set

    View the range of flange sets here:
    Extra gegevens
    PN 6 PN 10 PN 16 PN 25
    DN 65 A 160 185 185 185
    D1 130 145 145 145
    D2 110 122 122 122
    N x D 4 x 14 4 x 18 4 x 180 8 x 18
    PN 6 PN 10 PN 16 PN 25
    DN 80 A 190 200 200 200
    D1 150 160 160 160
    D2 128 138 138 138
    N x D 4 x 18 8 x 18 8 x 18 8 x 18
    PN 6 PN 10 PN 16 PN 25
    DN 100 A 210 220 220 235
    D1 170 180 180 190
    D2 148 158 158 162
    N x D 4 x 18 8 x 18 8 x 18 8 x 22
    PN 6 PN 10 PN 16 PN 25
    DN 125 A 240 250 250 270
    D1 200 210 210 220
    D2 178 188 188 188
    N x D 8 x 18 8 x 18 8 x 18 8 x 26
    PN 6 PN 10 PN 16 PN 25
    DN 150 A 265 285 285 300
    D1 225 240 240 250
    D2 202 212 212 218
    N x D 8 x 18 8 x 22 8 x 22 8 x 26
    PN 6 PN 10 PN 16 PN 25
    DN 175 A 315 315 330
    D1 270 270 280
    D2 242 242 248
    N x D 8 x 22 8 x 22 12 x 26
  • Duct cooler CSK160

    Kanaalkoeler CSK160 wordt toegepast in het luchttransportsysteem om lucht voor een bepaalde ruimte na te... Uitgelichte specificaties Uitvoering Rond Afmeting L x B x H 326 mm x 356 mm x 255 mm Kanaaldiameter ⌀ 160 mm
  • Extension cables

    View the range of extension cables here.
    Extra gegevens
    Extension cables Connection voltage Plug Length Diameter ATEX zone
    Default 230V 230V / 16A CEE 7/7 type E/F 25m 3*2.5mm² n/a
    230V 230V / 16A 230 V / 16 A – 3 pole 15m 3*2.5mm² n/a
    400V 400V / 16A 400 V / 16 A – 5 pin 25m 5*2.5mm² n/a
    400V 400V / 32A 400 V / 32 A – 5 pin 25m 5*6mm² n/a
    400V 400V / 63A 400 V / 63 A – 5 pin 25m 5*16mm² n/a
    400V 400V / 125A 400 V / 125 A – 5 pin 25m 5*35mm² n/a
    ATEX 42V 42V / 16A ATX 42V / 16A – 3 pin 25m 3*2.5mm² zone 1 and 21
    230V 230V / 16A CEAG 230 V / 16 A – 3 poles 25m 3*2.5mm² zone 1 and 21
    400V 400V / 16A CEAG 400 V / 16 A – 3 poles 25m 5*2.5mm² zone 1 and 21
    400V 400V / 32A CEAG 400 V / 32 A – 5 pin 25m 5*6mm² zone 1 and 21
    400V 400V / 63A CEAG 400 V / 63 A – 5 pin 25m 5*16mm² zone 1 and 21